product
Data book
Output (maximum) - well-catalogued. 230 v
Output power (maximum) - well-catalogued. General
PowiGaN?
The breakdown voltage
Protection function
Output configuration
The control mode
topology
Overheating reaction
Automatic restart and overpressure reactions
The product type
The input voltage.
The input voltage (minimum)
Operating temperature (maximum)
Operating temperature (minimum)
Internal switch
Automatic restart threshold
Pressure drop cable compensation
IC packaging
Output voltage (minimum)
The output voltage.
Switching frequency (maximum)
Switching frequency (minimum)
MSL level
Secondary response
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 45.0 W.
The Output Power (Max) - the Open Frame, Univ 50.0 W.
Breakdown Voltage 1700 V
Protection, the Features Input Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart, Latch Off
Product Type IC
Voltage - Input (Max) 1200 V
Voltage - Input (Min) 40 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart, Latch Off
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 65.0 W.
The Output Power (Max) - the Open Frame, Univ 70.0 W.
Breakdown Voltage 1700 V
Protection, the Features Input Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart, Latch Off
Product Type IC
Voltage - Input (Max) 1200 V
Voltage - Input (Min) 40 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart, Latch Off
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 100.0 W.
The Output Power (Max) - the Open Frame, Univ 85.0 W.
PowiGaN? Yes
Breakdown Voltage 750 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 100.0 W.
The Output Power (Max) - the Open Frame, Univ 85.0 W.
PowiGaN? Yes
Breakdown Voltage 750 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 12.0 W.
The Output Power (Max) - the Open Frame, Univ 10.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 12.0 W.
The Output Power (Max) - the Open Frame, Univ 10.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 12.0 W.
The Output Power (Max) - the Open Frame, Univ 10.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 15.0 W.
The Output Power (Max) - the Open Frame, Univ 12.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 15.0 W.
The Output Power (Max) - the Open Frame, Univ 12.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 15.0 W.
The Output Power (Max) - the Open Frame, Univ 12.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 25.0 W.
The Output Power (Max) - the Open Frame, Univ 20.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 25.0 W.
The Output Power (Max) - the Open Frame, Univ 20.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 25.0 W.
The Output Power (Max) - the Open Frame, Univ 20.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 30.0 W.
The Output Power (Max) - the Open Frame, Univ 25.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 30.0 W.
The Output Power (Max) - the Open Frame, Univ 25.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 30.0 W.
The Output Power (Max) - the Open Frame, Univ 25.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 30.0 W.
The Output Power (Max) - the Open Frame, Univ 25.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 40.0 W.
The Output Power (Max) - the Open Frame, Univ 36.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 40.0 W.
The Output Power (Max) - the Open Frame, Univ 36.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 40.0 W.
The Output Power (Max) - the Open Frame, Univ 36.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 40.0 W.
The Output Power (Max) - the Open Frame, Univ 36.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 45.0 W.
The Output Power (Max) - the Open Frame, Univ 40.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 45.0 W.
The Output Power (Max) - the Open Frame, Univ 40.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 45.0 W.
The Output Power (Max) - the Open Frame, Univ 40.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 45.0 W.
The Output Power (Max) - the Open Frame, Univ 40.0 W.
Breakdown Voltage 725 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 75.0 W.
The Output Power (Max) - the Open Frame, Univ 65.0 W.
PowiGaN? Yes
Breakdown Voltage 750 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 75.0 W.
The Output Power (Max) - the Open Frame, Univ 65.0 W.
PowiGaN? Yes
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 85.0 W.
The Output Power (Max) - the Open Frame, Univ 75.0 W.
PowiGaN? Yes
Breakdown Voltage 750 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CC
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold 90%
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 85.0 W.
The Output Power (Max) - the Open Frame, Univ 75.0 W.
PowiGaN? Yes
Breakdown Voltage 750 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 12.0 W.
The Output Power (Max) - the Open Frame, Univ 10.0 W.
Breakdown Voltage 900 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 25.0 W.
The Output Power (Max) - the Open Frame, Univ 20.0 W.
Breakdown Voltage 900 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart
The Data Sheet Look at the PDF
The Output Power (Max) - the Open Frame, 230 v 35.0 W.
The Output Power (Max) - the Open Frame, Univ 30.0 W.
Breakdown Voltage 900 V
Protection, the Features Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
The Output Profile CV
The Control Scheme Fluxlink
The Topology Flyback
The Over - Temperature Response Hysteretic
Auto - Restart & Overvoltage Response Auto - restart
Product Type IC
Voltage - Input (Max) 265 V
Voltage - Input (Min) 85 V
Temperature - Operating (Max) 150 ° c.
Temperature - Operating (Min) To 40 ° C
An Internal Switch Yes
Auto - Restart Threshold OL
Cable Drop Compensation 0 mV
IC Package InSOP - 24 d
The Voltage and the Output (Min) 5 V
Voltage and the Output (Max) 24 V
Switching Frequency (Max) 95 kHz
The Switching Frequency (min) 25 kHz
MSL Rating 3
Secondary Response Auto - restart

Product details

InnoSwitch3 - EP series IC can greatly simplify the development and manufacturing of low voltage high current power supply, especially those who use compact shell or need to meet the requirements of high efficiency of power supply.InnoSwitch的架构极具革新性,因为该器件同时将初级和次级控制器以及检测元件和符合安全标准的反馈机制集成到了单个IC中。装置整合了多种保护功能,包括线电压过压和欠压保护、输出过压和过电流限制,以及过温关机。此系列装置支援常见的锁定与自动重新启动机制组合,可满足多种应用的要求,如家电、伺服器待机、工业、电表、智慧电网、太阳能变频器和智慧型照明。

The product features

A highly integrated, compact appearance

  • In the full range of high efficiency
  • Integrated with multimodal quasi resonant (QR)/CCM flyback type controller, high voltage switch, secondary side detection and synchronous rectifier drives
  • Adopt double return to secondary feedback and synchronous FET, offer excellent multiplexed output cross regulation
  • Using FluxLink technology of internal integration, feedback and meet HIPOT (high voltage insulation)
  • Excellent constant voltage/constant current (CV/CC) precision, not affected by transformer design or peripheral components
  • The external current sense resistor, can set accurate constant current output

PowiGaN technology

EcoSmart, high efficiency and energy saving

  • No-load power consumption < 30 mW (including input sampling power consumption)
  • Easily meet all energy efficiency standards around the world
  • Low heat dissipation

Advanced protection/security features

  • The SR FET gate drive open circuit detection
  • Fast input undervoltage/over-voltage protection
  • Automatic restart output over-voltage/under-voltage protection
  • 725/750 V switch has excellent surge protection function
  • 900 V switch is suitable for the industrial design or enhance security

More optional features

  • Multiple undervoltage protection fault threshold

Full compliance with all safety requirements

  • Reinforced insulation
  • Dielectric strength > 4000 VAC
  • Product 100% HIPOT compliance testing
  • Through UL1577 and TUV (EN60950 EN62368) security certification
  • Can make the design to achieve A complete set of EN61000-4 test standard of grade A performance requirements, including EN61000-4-2, 4 - (30 V/m) 3, 4, 4-4-5, 4 to 6, 4 to 8 (100 A/m) and 4-9 (1000 A/m)

The related resources